A range hood's airflow rating assumes it is connected to the right duct. Put a strong fan on undersized or overly long ductwork and it gets louder while moving less air. The hood's installation manual specifies a duct size and a maximum run, and those are worth checking before the hood goes up.
Duct size follows the hood
Each hood or over-the-range microwave has an outlet sized for a particular duct:
- •Over-the-range microwaves: Usually rectangular duct measuring 3 1/4 by 10 inches, or round duct through a transition. Manuals set a minimum round size, commonly 6 inches.
- •Wall and under-cabinet hoods: Often 6-, 7- or 8-inch round, or rectangular, depending on fan size.
- •Large canopy and professional-style hoods: Often 8- or 10-inch round, sometimes larger.
The rule is simple: keep the duct at least as large as the hood's outlet all the way outside. Never step down with a reducer unless the manual allows it. One undersized section limits the entire run.
Equivalent length
Manuals limit the run in equivalent feet. Straight duct counts at its actual length. Each fitting is assigned a length that represents the resistance it adds:
- Measure every straight section, horizontal and vertical.
- Count the elbows and transitions, and note whether each elbow is 45 or 90 degrees.
- Look up each fitting's equivalent length in the manual's chart, along with the wall or roof cap.
- Add everything and compare the total with the manual's maximum.
Values differ between brands, sometimes significantly, so use only the chart for your model. Fewer elbows and shorter runs are always better, and many manufacturers recommend limiting elbows to just a few.
Materials and installation
- •Smooth rigid metal: Galvanized steel, stainless or aluminum with a smooth interior. Codes based on the IRC call for smooth, airtight metal kitchen exhaust duct.
- •Sealed joints: Seal seams with foil tape so grease and moisture stay inside.
- •Slope: Where possible, slope horizontal runs slightly toward the outside so condensation and grease do not pool at the hood.
- •Backdraft damper: The run must include a damper that opens when the fan runs and closes when it stops.
Where the duct ends
- •Outside only: The duct must end at a wall cap or roof cap outdoors. Never terminate it in an attic, wall cavity, crawl space or soffit, where grease and moisture will build up.
- •Caps: Choose a cap sized for the duct, with a damper that swings freely.
Ohio winters and attics
When a duct passes through an unheated attic or exterior wall, warm, moist air meets cold metal. In a central Ohio winter, that leads to condensation that can drip back into the hood or soak insulation. Insulating the duct where it runs through cold spaces helps, as does keeping the run short.
Makeup air
Codes based on the IRC generally require makeup air for kitchen exhaust above 400 cubic feet per minute. Before upgrading to a bigger fan and larger duct, ask your building department what applies. Height also affects capture, covered in how high to hang a hood.
Signs your duct is holding the hood back
- •Loud fan, weak draw. Smoke escapes at high speed.
- •A damper flap that rattles or sticks.
- •Grease dripping from the hood or the outside cap.
- •Cold drafts coming down through the hood in winter.
Who does the work
Cutting through exterior walls or roofs and flashing a roof cap is contractor or roofer work. Enlarging a duct through framing may need a permit. A new hood circuit belongs to a licensed electrician.
If the ductwork is right and the hood fan hums, runs slowly or will not start, or an over-the-range microwave fan has failed, our technicians can diagnose it and quote the repair first. See our microwave repair and range repair pages to book.